The Siglent SEM5014A series electronic calibrator covering the frequency bands of 9kHz to 9GHz has a USB interface for communication and power supply, and has SMA RF connectors. It is suitable for calibration and error correction of SHA800A series, SVA1000X series, SNA5000X series, SNA5000A series, and SNA6000A series vector network analyzers of Siglent Technology Co., Ltd

Efficient and accurate: Traditional mechanical calibration methods require the operator to connect and disconnect the instrument to be measured several times using calibration devices. This not only increases the calibration time, but also the frequency of operation and the probability of human error. When calibrating with electronic calibrators, the operator only needs to make one connection - at the very beginning, the port of the electronic calibrator is connected to the test port - which significantly reduces the number of connections made during the calibration process, making the process much simpler and more efficient. As the number of connections decreases, the probability of operator error is reduced, as is the probability of connector wear and tear, which in turn reduces the cost of port connector maintenance.

Quick and easy operation of the ECal module

Example setup:

The ECal module is connected to the vector network analyzer via a USB cable (supplied as an accessory) and the vector network analyzer then provides control and power via the USB cable. When connecting the electronic calibrator to the vector network analyzer, the vector network analyzer will automatically recognize the calibrator type, frequency range and connector type. When the connection is completed if the WAIT indicator (red) lights on, it means that the ECal module has not reached the normal operating temperature and needs to wait until the ECal reaches the normal operating temperature before it can be used; if the READY indicator (green) lights on, it means that the ECal module has reached the normal operating temperature and can be used normally. Disconnect: Simply disconnect the USB cable to stop the ECal module from working. Then simply disconnect the RF connector at ports A, B, C and D.

Calibration Kit SEM5014A

To order
SKU: 408018
Calibration Kit: 3.5mm (female), 9 kHz - 9 GHz, 4 ports
5 814.00 $
Sign in
to add this item to wishlist
Notify me when back in stock
Sign in to
add the product to the waiting list
Features
Type  E-Cal
Frequency range  9kHz - 9GHz
Connector  3.5mm (female)