Main specifications
| Parameters |
Min |
Typical |
Max |
Units |
| Frequency |
DC |
~ |
8 |
GHz |
| Attenuation |
39.1 |
40 |
40.9 |
dB |
| VSWR |
|
|
1.25 |
|
Other parameters
| Power Capacity |
300W Design assurance |
| Impedance |
50Ω |
| Connector |
N -JK |
| Connector material |
Stainless steel |
| Surface |
Black |
| Product shell material |
Aluminum |
| Operation Temp. |
-40~+85℃ Design assurance |
| Other |
In Port N-J |
Note
1. When installing attenuators, it is necessary to consider sufficient heat dissipation space and avoid installing them next to equipment with high heat output, otherwise the power capacity will decrease;
2. Small power attenuators do not have input and output directions, nor do they indicate directions. When high-power attenuators have input and output port markings, they must be connected to the equipment in the specified direction, otherwise the attenuator may burn out.
Power Derating Curve

Reference picture

Configuration(mm)

Typical test curve